Exfo QA-805 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Exfo QA-805 herunter. EXFO QA-805 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - CM Interface Module

User GuideQA-805 andW2CM Interface Module

Seite 2

Introduction2 QA-805 and W2CM Interface ModuleFront View of QA-805Front View of QA-805This image of the QA-805 chassis provides a realistic view of th

Seite 3 - Contents

IntroductionQualityAssurer 805 3Rear View of QA-805Rear View of QA-805This image of the rear panel on the QA-805 provides a realistic view of the back

Seite 4

Introduction4 QA-805 and W2CM Interface ModulePhysical Description of QA-805 UnitPhysical Description of QA-805 UnitChassis Front PanelThe following i

Seite 5 - Certification Information

IntroductionQualityAssurer 805 5Physical Description of QA-805 Unit10. Power supply unit/slot 211. Power supply unit/slot 312. Power supply unit/slot

Seite 6

Introduction6 QA-805 and W2CM Interface ModulePhysical Description of QA-805 UnitBackplaneThe QA-805 provides a monolithic backplane. Power and high s

Seite 7

IntroductionQualityAssurer 805 7Physical Description of QA-805 UnitRear FRU Physical LayoutLogic GroundLogic ground is used as reference for low volta

Seite 8

Introduction8 QA-805 and W2CM Interface ModulePhysical Description of QA-805 UnitNote: The screw is installed by default.

Seite 9 - 1Introduction

IntroductionQualityAssurer 805 9Cooling AssemblyCooling AssemblyFan TrayThere are 2 fan tray cassettes in the system. The cooling is performed side to

Seite 10 - Front View of QA-805

Introduction10 QA-805 and W2CM Interface ModuleCooling AssemblyThe following depicts the fan tray with air filter frame:To remove the fan tray:1. Loos

Seite 11 - Rear View of QA-805

IntroductionQualityAssurer 805 11Cooling AssemblyCAUTIONRotating fan blades can cause injury or cut. Keep hands clear when servicing. Allow time for f

Seite 12 - Chassis Front Panel

ii QA-805 and W2CM Interface ModuleCopyright © 2013 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieva

Seite 13 - Chassis Back Panel

Introduction12 QA-805 and W2CM Interface ModuleCooling AssemblyAir FilterThe air filter provides: Filtration of intake air from dust particles Addit

Seite 14 - Physical Layout

IntroductionQualityAssurer 805 13Power SuppliesPower SuppliesUp to 4 AC power supplies can be plugged in the shelf. The Blutek BPA-R850-480A power sup

Seite 15 - Logic Ground

Introduction14 QA-805 and W2CM Interface ModulePower SuppliesPowering the ShelfFor each power supply, a separate AC inlet as well as switch is provide

Seite 16 - Introduction

IntroductionQualityAssurer 805 15QA-805 Technical SpecificationsQA-805 Technical SpecificationsPhysical Dimensions Width: 482.60 mm (19 in) Height:

Seite 17 - Cooling Assembly

Introduction16 QA-805 and W2CM Interface ModuleConventionsConventionsBefore using the product described in this guide, you should understand the follo

Seite 18

QualityAssurer 805 172 Safety InformationLaser Safety WarningsYour instrument is a Class 1 laser product in compliance with standards IEC 60825-1 2007

Seite 19

Safety Information18 QA-805 and W2CM Interface ModuleOperating CautionsOperating CautionsCAUTIONUse only EXFO-supplied or approved Class 1 SFP, SFP+,

Seite 20 - Air Filter

Safety InformationQualityAssurer 805 19Installation Instruction WarningsInstallation Instruction WarningsRack MountingIf rack mounted units are instal

Seite 21 - Power Supplies

Safety Information20 QA-805 and W2CM Interface ModuleInstallation Instruction WarningsCard InstallationCards installed in the QA-805 unit are hot-swap

Seite 22 - Powering the Shelf

Safety InformationQualityAssurer 805 21Equipment RatingsEquipment RatingsEquipment RatingsTemperature Operation Storage 0 °C to 40 °C (32 °F to 104

Seite 23 - Shelf Management

QualityAssurer 805 iiiContentsCertification Information ...

Seite 25 - 2 Safety Information

QualityAssurer 805 233 Getting StartedShelf InstallationConsider the following guidelines:1. Install the system only in an area with restricted access

Seite 26 - Operating Cautions

Getting Started24 QA-805 and W2CM Interface ModuleTurning the Unit On/OffTurning Off the UnitTo safely turn off the QA-805, please ensure the followin

Seite 27 - Input Supply

QualityAssurer 805 254W2CM-10Gb Ethernet Interface SeriesThe W2CM-10GbE module tests fixed-mobile converged networks and services like wireless (2G/3G

Seite 28 - Card Installation

W2CM-10Gb Ethernet Interface Series26 QA-805 and W2CM Interface ModuleModule InstallationW2CM-10GbE Lite/W2CM-4GbE 1-slot moduleModule InstallationThe

Seite 29 - Equipment Ratings

W2CM-10Gb Ethernet Interface SeriesQualityAssurer 805 27Module Installation6. Ensure levers fully lock into the closed position. If the chassis is pow

Seite 30

W2CM-10Gb Ethernet Interface Series28 QA-805 and W2CM Interface Module10/100/1000 M Copper and 1 G Optical Interfaces (SFP)10/100/1000 M Copper and 1

Seite 31 - 3 Getting Started

W2CM-10Gb Ethernet Interface SeriesQualityAssurer 805 2910/100/1000 M Copper and 1 G Optical Interfaces (SFP)LED definition for 1 G optical SFP:10/100

Seite 32 - Turning On the Unit

W2CM-10Gb Ethernet Interface Series30 QA-805 and W2CM Interface Module10/100/1000 M Copper and 1 G Optical Interfaces (SFP)1 G Optical SFPThe followin

Seite 33 - CM-10Gb Ethernet Interface

W2CM-10Gb Ethernet Interface SeriesQualityAssurer 805 3110 G LAN/WAN Optical Interfaces (SFP+)10 G LAN/WAN Optical Interfaces (SFP+)Two Class 1 Laser

Seite 34 - Module Installation

iv QA-805 and W2CM Interface Module7 Warranty ...39

Seite 35 - Extracting a Module

W2CM-10Gb Ethernet Interface Series32 QA-805 and W2CM Interface Module10 G LAN/WAN Optical Interfaces (SFP+)LED definition for 10 G optical SFP+:LED#

Seite 36 - Interfaces (SFP)

QualityAssurer 805 335 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean them

Seite 37 - 10/100/1000 M Copper SFP

Maintenance34 QA-805 and W2CM Interface ModuleFan Tray ReplacingTo replace the ATCA card cage air filter, perform the following:1. Slowly remove the r

Seite 38 - 1 G Optical SFP

MaintenanceQualityAssurer 805 35Recycling and Disposal (Applies to European Union Only)Recycling and Disposal (Applies to European Union Only)For comp

Seite 40 - LED# Label Color Definition

QualityAssurer 805 376 TroubleshootingContacting the Technical Support GroupTo obtain after-sales service or technical support for this product, conta

Seite 41 - 5 Maintenance

Troubleshooting38 QA-805 and W2CM Interface ModuleTransportationTransportationMaintain a temperature range within specifications when transporting the

Seite 42 - Power Supply Replacing

QualityAssurer 805 397 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period of

Seite 43 - Recycling and Disposal

Warranty40 QA-805 and W2CM Interface ModuleLiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be

Seite 44

WarrantyQualityAssurer 805 41ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any t

Seite 45 - 6 Troubleshooting

Certification InformationQualityAssurer 805 vCertification InformationNorth America Regulatory StatementThis unit was certified by an agency approved

Seite 46 - Transportation

Warranty42 QA-805 and W2CM Interface ModuleService and RepairsService and RepairsEXFO commits to providing product service and repair for five years f

Seite 47 - 7 Warranty

WarrantyQualityAssurer 805 43EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest auth

Seite 49

QualityAssurer 805 45A Technical SpecificationsQualityAssurer - QA-805IMPORTANTThe following technical specifications can change without notice. The i

Seite 50 - Service and Repairs

Technical Specifications46 QA-805 and W2CM Interface ModuleW2CM 10 Gigabit Ethernet Interface SeriesW2CM 10 Gigabit Ethernet Interface SeriesTest solu

Seite 51 - QualityAssurer 805 43

IndexQualityAssurer 805 47IndexAAC requirements ... 21after-sales service ...

Seite 52

Index48 QA-805 and W2CM Interface ModuleWwarrantycertification ... 41exclusions ...

Seite 53 - A Technical Specifications

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Seite 54 - Technical Specifications

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This Exfo product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Seite 55 - QualityAssurer 805 47

www.EXFO.com · [email protected]/N: 1063196CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Seite 56

Certification Informationvi QA-805 and W2CM Interface Module Page 1 of 1 DECLARATION OF CONFORMITY Application of Council Directive(s): 1999/5/EC

Seite 57

Certification InformationQualityAssurer 805 vii Page 1 of 1 DECLARATION OF CONFORMITY Application of Council Directive(s): 1999/5/EC – The R&T

Seite 59

QualityAssurer 805 11IntroductionEXFO’s QualityAssurer™ QA-805 is targeted at NEMs and NSPs that are developing and deploying IMS and wireless network

Kommentare zu diesen Handbüchern