User Guide Power Meter/Light Source/Optical Loss Test SetFPM/FLS/FOT-600
Introducing the FPM/FLS/FOT-6004 FPM/FLS/FOT-600Typical ApplicationsTypical Applications Transmitter power measurements (dBm and W) Fiber-link loss
Introducing the FPM/FLS/FOT-600Power Meter/Light Source/Optical Loss Test Set 5ConventionsConventionsBefore using the product described in this guide,
Power Meter/Light Source/Optical Loss Test Set 72 Safety Information WARNINGDo not install or terminate fibers while a light source is active. Never l
Safety Information8 FPM/FLS/FOT-600Laser Safety Information (FLS-600 and FOT-600 without VFL)Laser Safety Information (FLS-600 and FOT-600 without VFL
Safety InformationPower Meter/Light Source/Optical Loss Test Set 9Laser Safety Information (Units with VFL)Laser Safety Information (Units with VFL) Y
Safety Information10 FPM/FLS/FOT-600Electrical Safety InformationEquipment RatingsTemperature Operation Storage-0 °C to 40 °C (32 °F to 104 °F)-40 °
Power Meter/Light Source/Optical Loss Test Set 113 Getting StartedTurning the Unit On and OffWhen you turn off the FPM-600 or the FOT-600, it saves th
Getting Started12 FPM/FLS/FOT-600Turning the Unit On and OffLED IndicatorsFPM/FOT-600:Whether the test passed or failed according to the thresholdsFLS
Getting StartedPower Meter/Light Source/Optical Loss Test Set 13Activating Automatic Shutdown (Auto-Off)Activating Automatic Shutdown (Auto-Off)When a
ii FPM/FLS/FOT-600Copyright © 2003–2013 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or
Getting Started14 FPM/FLS/FOT-600Activating the BacklightActivating the BacklightWhen operating the unit in the dark, use the backlight to make data o
Getting StartedPower Meter/Light Source/Optical Loss Test Set 15Accessing and Navigating Setup MenusPM DATA SRCP/FFAVCFCAB1*FAVPREFNormal ModeFOT-600*
Getting Started16 FPM/FLS/FOT-600Installing the EXFO Universal Interface (EUI)Installing the EXFO Universal Interface (EUI)The EUI fixed baseplate is
Getting StartedPower Meter/Light Source/Optical Loss Test Set 17Cleaning and Connecting Optical FibersCleaning and Connecting Optical FibersTo connect
Getting Started18 FPM/FLS/FOT-600Cleaning and Connecting Optical Fibers3. Carefully align the connector and port to prevent the fiber end from touchin
Power Meter/Light Source/Optical Loss Test Set 194 Measuring Power or Loss (FPM-600 and FOT-600)Nulling Electrical OffsetsTemperature and humidity var
Measuring Power or Loss (FPM-600 and FOT-600)20 FPM/FLS/FOT-600Setting Power Correction FactorSetting Power Correction FactorYou may apply a correctio
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 21Setting Power Correction Factor5. Edit the correction fa
Measuring Power or Loss (FPM-600 and FOT-600)22 FPM/FLS/FOT-600Defining a List of Favorite WavelengthsDefining a List of Favorite WavelengthsYou must
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 23Defining a List of Favorite Wavelengths4. Press to inc
Power Meter/Light Source/Optical Loss Test Set iiiContentsCertification Information ...
Measuring Power or Loss (FPM-600 and FOT-600)24 FPM/FLS/FOT-600Referencing Your Power Meter to a SourceReferencing Your Power Meter to a SourceIn refe
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 25Referencing Your Power Meter to a SourceTo reference the
Measuring Power or Loss (FPM-600 and FOT-600)26 FPM/FLS/FOT-600Referencing Your Power Meter to a Source5. Repeat the procedure for each wavelength you
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 27Measuring Power or LossMeasuring Power or LossMeasuring
Measuring Power or Loss (FPM-600 and FOT-600)28 FPM/FLS/FOT-600Measuring Power or Loss6. Match the source and power meter wavelengths: If the source
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 29Automatically Detecting WavelengthAutomatically Detectin
Measuring Power or Loss (FPM-600 and FOT-600)30 FPM/FLS/FOT-600Activating Hold Min/Max Power ModeActivating Hold Min/Max Power ModeWith the Hold Min/M
Measuring Power or Loss (FPM-600 and FOT-600)Power Meter/Light Source/Optical Loss Test Set 31Setting Pass/Fail ThresholdsSetting Pass/Fail Thresholds
Measuring Power or Loss (FPM-600 and FOT-600)32 FPM/FLS/FOT-600Setting Pass/Fail Thresholds6. Edit the pass/fail threshold as follows:6a. Hold down
Power Meter/Light Source/Optical Loss Test Set 335 Using a Light Source (FLS-600 and FOT-600) or VFLThe FLS-600 may contain up to three sources (one-p
iv FPM/FLS/FOT-6006 Saving and Recalling Power/Loss Values ...39Setting Autonaming Scheme ...
Using a Light Source (FLS-600 and FOT-600) or VFL34 FPM/FLS/FOT-600Activating/Deactivating a Light Source or VFLActivating/Deactivating a Light Source
Using a Light Source (FLS-600 and FOT-600) or VFLPower Meter/Light Source/Optical Loss Test Set 35Using Auto-Switching ModeNote: Auto-switching mode i
Using a Light Source (FLS-600 and FOT-600) or VFL36 FPM/FLS/FOT-600Sending Source Power Value with SignalSending Source Power Value with SignalYour so
Using a Light Source (FLS-600 and FOT-600) or VFLPower Meter/Light Source/Optical Loss Test Set 37Sending Source Power Value with SignalTo define the
Using a Light Source (FLS-600 and FOT-600) or VFL38 FPM/FLS/FOT-600Sending Source Power Value with SignalTo use the source’s actual output power as re
Power Meter/Light Source/Optical Loss Test Set 396 Saving and Recalling Power/Loss ValuesYou can save 1000 power/loss values in your unit, along with
Saving and Recalling Power/Loss Values40 FPM/FLS/FOT-600Saving, Recalling and Deleting DataSaving, Recalling and Deleting DataTo save a power/loss val
Saving and Recalling Power/Loss ValuesPower Meter/Light Source/Optical Loss Test Set 41Saving, Recalling and Deleting Data To recall saved data:1. Fro
Saving and Recalling Power/Loss Values42 FPM/FLS/FOT-600Saving, Recalling and Deleting DataTo delete a single saved value from the unit:1. From normal
Saving and Recalling Power/Loss ValuesPower Meter/Light Source/Optical Loss Test Set 43Transferring Data to a ComputerTo delete all saved data from th
Power Meter/Light Source/Optical Loss Test Set vCertification InformationCertification InformationNorth America Regulatory StatementThis unit was cert
Power Meter/Light Source/Optical Loss Test Set 457 MaintenanceThis product contains no user-serviceable parts. However, it contains sensitive electron
Maintenance46 FPM/FLS/FOT-600Cleaning EUI ConnectorsTo clean EUI connectors:1. Remove the EUI from the instrument to expose the connector baseplate an
MaintenancePower Meter/Light Source/Optical Loss Test Set 47Cleaning EUI Connectors6. Clean the ferrule in the connector port as follows:6a. Deposit o
Maintenance48 FPM/FLS/FOT-600Cleaning Fixed ConnectorsCleaning Fixed ConnectorsRegular cleaning of connectors will help maintain optimum performance.
MaintenancePower Meter/Light Source/Optical Loss Test Set 49Cleaning Fixed Connectors5. Throw out the wiping cloths after one use.6. Moisten a cleanin
Maintenance50 FPM/FLS/FOT-600Cleaning VFL-Type ConnectorsCleaning VFL-Type ConnectorsVFL-type connectors are fixed on your unit and can be cleaned usi
MaintenancePower Meter/Light Source/Optical Loss Test Set 51Cleaning Detector PortsCleaning Detector PortsRegular cleaning of detectors will help main
Maintenance52 FPM/FLS/FOT-600Recharging and Replacing the BatteryRecharging and Replacing the BatteryThe Li-Ion battery will last about 70 hours (powe
MaintenancePower Meter/Light Source/Optical Loss Test Set 53Recharging and Replacing the BatteryTo replace the battery:1. Turn off the unit (if the AC
vi FPM/FLS/FOT-600Certification InformationEuropean Community Declaration of Conformity Page 1 of 1 DECLARATION OF CONFORMITY Application of Counci
Maintenance54 FPM/FLS/FOT-600Recalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025
Power Meter/Light Source/Optical Loss Test Set 558 TroubleshootingSolving Common ProblemsProblem Possible Cause SolutionThe unit does not turn on. Y
Troubleshooting56 FPM/FLS/FOT-600Reverting Unit to Factory SettingsReverting Unit to Factory SettingsYou can revert most parameters on your unit to th
TroubleshootingPower Meter/Light Source/Optical Loss Test Set 57Error Codes and DescriptionsError Codes and Descriptions ER: error code displayed unt
Troubleshooting58 FPM/FLS/FOT-600Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technica
TroubleshootingPower Meter/Light Source/Optical Loss Test Set 59TransportationTransportationMaintain a temperature range within specifications when tr
Power Meter/Light Source/Optical Loss Test Set 619 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and
Warranty62 FPM/FLS/FOT-600LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for a
WarrantyPower Meter/Light Source/Optical Loss Test Set 63ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of
Power Meter/Light Source/Optical Loss Test Set 11 Introducing the FPM/FLS/FOT-600This user guide covers the following products (unless otherwise speci
Warranty64 FPM/FLS/FOT-600Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date
WarrantyPower Meter/Light Source/Optical Loss Test Set 65EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicin
Power Meter/Light Source/Optical Loss Test Set 67A Technical Specifications FPM-600IMPORTANTThe following technical specifications can change without
Technical Specifications68 FPM/FLS/FOT-600FLS-600FLS-600SPECIFICATIONS aModel 12D 23BL 234BL 235BLCentral wavelength (nm) 850 ± 251300 +50/–101310 ± 2
Technical SpecificationsPower Meter/Light Source/Optical Loss Test Set 69FOT-600FOT-600SPECIFICATIONS aModel FOT-602XDetector GeXPower range (dBm) b26
NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT
MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( )Logo㪖㉦This Exfo product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl
www.EXFO.com · [email protected]/N: 1064230CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418
Introducing the FPM/FLS/FOT-6002 FPM/FLS/FOT-600Main FeaturesModulated signal emission or detection (270 Hz, 1 kHz and 2 kHz) compatible with other EX
Introducing the FPM/FLS/FOT-600Power Meter/Light Source/Optical Loss Test Set 3Power SourcesPower SourcesThe units operate with the following power so
Kommentare zu diesen Handbüchern