Exfo FTB-635 Wideband Copper and DSL Test Module Bedienungsanleitung Seite 148

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 373
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 147
Multimeter Tests
140 FTB-635
Current Test
Setting Threshold Values
The Test Threshold page allows you to set the Threshold Current for
each pair.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Multimeter test
.
2. From the Tests menu, select Current test.
3. Tap Continuous DC or Continuous AC tab for which you want to set
the Threshold values.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the Threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.
Threshold Current sets the threshold value.
Seitenansicht 147
1 2 ... 143 144 145 146 147 148 149 150 151 152 153 ... 372 373

Kommentare zu diesen Handbüchern

Keine Kommentare