Exfo FTB-7000 OTDR Series for FTB-500 Bedienungsanleitung Seite 244

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 482
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 243
Analyzing Bidirectional Traces
230 OTDR
Creating Bidirectional Trace Files
Creating Bidirectional Trace Files
To work with the OTDR Bidirectional Analysis utility, you must acquire and
save the traces (in the OTDR application) before opening them with the
Bidirectional Analysis utility.
You can open unidirectional trace files to combine them into a
bidirectional trace. It is possible to use both single-wavelength and
multiwavelength traces. However, once a multiwavelength trace file is
recalled, it is converted to a single-wavelength trace file and you will have
to specify which wavelength the application will use. Bidirectional files will
automatically be created for the other wavelengths. You can save these
bidirectional files or discard them.
Seitenansicht 243
1 2 ... 239 240 241 242 243 244 245 246 247 248 249 ... 481 482

Kommentare zu diesen Handbüchern

Keine Kommentare