Exfo PM-1100 Optical Power Meter Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Exfo PM-1100 Optical Power Meter herunter. EXFO PM-1100 Optical Power Meter User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 111
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
P/N: 1051923 January 2008 1/4
ADDENDUM
This information applies only to the
PM-1100 Optical Power Meter user guide.
GPIB Commands and Queries
³ The FORM:READ:DATA? query does not exist.
³ The MMEM:ACQ:DATA:RECA:VALUE? query should be defined as
follows:
MMEMory:ACQuisition:DATA:RECAll:VALUE?
Description This query returns the measurement saved in the <data>
memory location.
Syntax MMEM:ACQ:DATA:RECA:VALUE?<space><data>
Parameters The <data> parameter represents the memory location where
measurement data is stored (out of the 1024 available).
Response Measurement data saved in the specified memory location in
the “±999.999E±99” format.
Notes
³ Use the MMEM:ACQ:DATA:RECA:UNIT? query to get the
corresponding measurement units.
³ Use the MMEM:ACQ:DATA:RECA:WAVE? query to get the
wavelength at which the measurement was taken.
Example MMEM:ACQ:DATA:RECA:VALUE? 1021
Seitenansicht 0
1 2 3 4 5 6 ... 110 111

Inhaltsverzeichnis

Seite 1 - ADDENDUM

P/N: 1051923 January 2008 1/4ADDENDUMThis information applies only to thePM-1100 Optical Power Meter user guide.GPIB Commands and Queries³ The FORM:RE

Seite 2 - MMEMory:ACQuisition:SAMPles

Certification Informationvi PM-1100Application of Council Directive(s): 73/23/EEC - The Low Voltage Directive89/336/EEC - The EMC DirectiveManufacture

Seite 3 - SENSitivity:POWer:WAVElength?

Remote Control Commands90 PM-1100Product-Specific Commands—DescriptionSENSitivity:FREQuency:CATalog?Description This query returns a list of available

Seite 4

Remote Control CommandsOptical Power Meter 91Product-Specific Commands—DescriptionSENSitivity:POWer:REFerence:STATeDescription This command selects wh

Seite 5 - OPTICAL POWER METER

Remote Control Commands92 PM-1100Product-Specific Commands—DescriptionSENSitivity:POWer:UNITDescription This command changes the measurement units.Syn

Seite 6

Remote Control CommandsOptical Power Meter 93Product-Specific Commands—DescriptionSENSitivity:POWer:WAVelengthDescription This command selects a new o

Seite 7 - Contents

Remote Control Commands94 PM-1100Product-Specific Commands—DescriptionSYSTem:VERSion?Description This query returns the current system software versio

Seite 8

Optical Power Meter 95C SCPI-Based ErrorsError NumberDescription Probable Cause-100 “Command error.” An error occurred while validating a command.-101

Seite 9

SCPI-Based Errors96 PM-1100-300 “Invalid state.” The state of the PM-1100 is not compatible with the command sent.-300 “Invalid sampling rate.” The re

Seite 10 - DECLARATION OF CONFORMITY

IndexOptical Power Meter 97IndexAabsolute power measurements ... 15AC requirements ... 10acquisi

Seite 11 - Optical Power Meter

Index98 PM-1100error messages in remote control... 47EXFO service centers... 64EXFO Web site...

Seite 12 - Front Panel

IndexOptical Power Meter 99programming an acquisition ... 23protective cap ... 50Rrecali

Seite 13 - Back Panel

Optical Power Meter 11 Introducing the PM-1100 Optical Power MeterThe PM-1100 Optical Power Meter provides accurate power measurements over a wide dyn

Seite 14 - RS-232 Connector Pinout

Index100 PM-1100Ttechnical specifications ... 57, 65technical support ... 58temperature for

Seite 15 - IMPORTANT

Printed in Canada (2006-09)www.EXFO.com · [email protected]© 2006 EXFO Electro-Optical Engineering Inc. All rights reserved.P/N: 1048634CORPORATEHEADQUA

Seite 16

Introducing the PM-1100 Optical Power Meter2 PM-1100Front PanelFront PanelNote: Your Optical Power Meter may slightly differ from the illustration.Mea

Seite 17 - 2 Safety Information

Introducing the PM-1100 Optical Power MeterOptical Power Meter 3Back PanelBack PanelNote: Your PM-1100 may slightly differ from the illustration.Groun

Seite 18

Introducing the PM-1100 Optical Power Meter4 PM-1100RS-232 Connector PinoutRS-232 Connector PinoutThe RS-232 connector (serial port) at the back of th

Seite 19 - Optical Power Meter 9

Introducing the PM-1100 Optical Power MeterOptical Power Meter 5ConventionsConventionsBefore using the product described in this manual, you should un

Seite 21 - 3 Getting Started with Your

Optical Power Meter 72 Safety InformationLaser Safety InformationWARNINGDo not install or terminate fibers while a light source is active. Never look

Seite 22

Safety Information8 PM-1100Electrical Safety InformationElectrical Safety InformationThis unit uses an international safety standard three-wire power

Seite 23

Safety InformationOptical Power Meter 9Electrical Safety InformationWARNING³ Use this unit indoors only.³ Position the unit so that the air can circul

Seite 24

P/N: 1051923 January 2008 2/4³The MMEM:ACQ:DATA:RECA:WAV? query should be named and defined as follows:³ The MMEM:ACQ:SAMP command should be defined a

Seite 25 - Measuring Absolute Power

Safety Information10 PM-1100Electrical Safety InformationThe following label is located on the back panel of the unit:Equipment RatingsTemperature³ Op

Seite 26 - Relative Power

Optical Power Meter 113 Getting Started with Your Optical Power MeterTurning On and Off the Optical Power MeterBefore turning the Optical Power Meter

Seite 27

Getting Started with Your Optical Power Meter12 PM-1100Selecting a Menu or a Menu OptionSelecting a Menu or a Menu OptionThe blue buttons to the right

Seite 28 - 18 PM-1100

Optical Power Meter 134 Operating the Optical Power MeterCleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1. Clean t

Seite 29 - Storing Data Manually

Operating the Optical Power Meter14 PM-1100Nulling Electrical OffsetsNulling Electrical OffsetsThe offset nulling process provides a zero-power refere

Seite 30 - 20 PM-1100

Operating the Optical Power MeterOptical Power Meter 15Measuring Absolute PowerMeasuring Absolute PowerPress dBm/Watt to display the absolute power of

Seite 31

Operating the Optical Power Meter16 PM-1100Relative PowerRelative PowerIn relative mode, the Optical Power Meter compares the power of the signal rece

Seite 32

Operating the Optical Power MeterOptical Power Meter 17Relative PowerWhen you access relative mode, the Optical Power Meterdisplays the last reference

Seite 33 - Programming an Acquisition

Operating the Optical Power Meter18 PM-1100Relative PowerEntering a Specific Reference ValueTo enter a specfic reference value:1. Use λ to select the

Seite 34 - 24 PM-1100

Operating the Optical Power MeterOptical Power Meter 19Average ModeAverage ModeChoose Avg in order for the displayed power measurement to be averaged

Seite 35

P/N: 1051923 January 2008 3/4³The SENS:FREQ:CAT? query should be named and defined as follows:³ The SENS:POW:WAV command should be named and defined a

Seite 36

Operating the Optical Power Meter20 PM-1100Recalling Manually Stored DataRecalling Manually Stored DataThe data you stored manually (see Storing Data

Seite 37

Operating the Optical Power MeterOptical Power Meter 21Recalling Manually Stored Data3. Press ENTER. The selected register will be displayed.Note: A d

Seite 38 - Recalling Acquisition Data

Operating the Optical Power Meter22 PM-1100Erasing Manually Stored DataErasing Manually Stored DataThe manually stored data (up to 512) can only be er

Seite 39

Operating the Optical Power MeterOptical Power Meter 23Programming an AcquisitionProgramming an AcquisitionYou can program the PM-1100 to automaticall

Seite 40

Operating the Optical Power Meter24 PM-1100Programming an AcquisitionTo program an acquisition:1. Press Program. You will see the following display:2.

Seite 41 - Optical Power Meter 31

Operating the Optical Power MeterOptical Power Meter 25Programming an Acquisition4. Set the duration of the acquisition.4a. Press ENTER. The first dig

Seite 42 - Changing the Sampling Rate

Operating the Optical Power Meter26 PM-1100Starting the AcquisitionStarting the AcquisitionWhen you start an acquisition, data is acquired in the curr

Seite 43 - You can scroll up or down

Operating the Optical Power MeterOptical Power Meter 27Stopping the AcquisitionStopping the AcquisitionOnce the acquisition starts, it continues until

Seite 44 - 34 PM-1100

Operating the Optical Power Meter28 PM-1100Recalling Acquisition DataRecalling Acquisition DataThe data stored during a programmed acquisition (see Pr

Seite 45 - Setting an Offset

Operating the Optical Power MeterOptical Power Meter 29Recalling Acquisition Data3. Using the up/down arrows, scroll to the register number you want t

Seite 46 - Setting the Date

P/N: 1051923 January 2008 4/4³The UNIT:POW command should be named and defined as follows:³ The Quick Reference Command Tree should be modified as fol

Seite 47 - Setting the Clock

Operating the Optical Power Meter30 PM-1100Erasing Acquisition DataErasing Acquisition DataThe data stored through a programmed acquisition (up to 102

Seite 48 - Setting the Display Intensity

Operating the Optical Power MeterOptical Power Meter 31Customizing Your Optical Power MeterTo change the resolution:1. Press Setup. You will see the f

Seite 49 - Saving a Configuration

Operating the Optical Power Meter32 PM-1100Customizing Your Optical Power MeterChanging the Sampling RateYou can set the number of samples taken by th

Seite 50 - Recalling a Configuration

Operating the Optical Power MeterOptical Power Meter 33Customizing Your Optical Power MeterCustomizing the Shortlist of WavelengthsThe Optical Power M

Seite 51 - Power Meter Remotely

Operating the Optical Power Meter34 PM-1100Customizing Your Optical Power MeterTo erase one wavelength from the shortlist:1. Press Setup.2. Scroll (le

Seite 52 - 42 PM-1100

Operating the Optical Power MeterOptical Power Meter 35Customizing Your Optical Power MeterSetting an OffsetAn offset can be applied to any measuremen

Seite 53 - Communication Parameters

Operating the Optical Power Meter36 PM-1100Customizing Your Optical Power MeterSetting the DateThe date must be entered according to the year-month-da

Seite 54

Operating the Optical Power MeterOptical Power Meter 37Customizing Your Optical Power MeterSetting the ClockThe time must be entered according to the

Seite 55 - Optical Power Meter 45

Operating the Optical Power Meter38 PM-1100Customizing Your Optical Power MeterSetting the Display IntensityDisplay intensity may be set to high or lo

Seite 56 - Command Structure

Operating the Optical Power MeterOptical Power Meter 39Customizing Your Optical Power MeterSaving a ConfigurationOnce the PM-1100 is customized for a

Seite 57 - Error Messages

USER GUIDEOPTICAL POWER METERPM-1100R&D AND MANUFACTURING

Seite 58

Operating the Optical Power Meter40 PM-1100Customizing Your Optical Power MeterRecalling a ConfigurationOnce you have saved a configuration (see Savin

Seite 59 - 6 Maintenance

Optical Power Meter 415 Controlling Your Optical Power Meter Remotely³ The Optical Power Meter can be remotely controlled either by³ a GPIB interface

Seite 60

Controlling Your Optical Power Meter Remotely42 PM-1100Setting the Optical Power Meter for Remote ControlSetting the Optical Power Meter for Remote Co

Seite 61 - Replacing Fuses

Controlling Your Optical Power Meter RemotelyOptical Power Meter 43Communication ParametersCommunication ParametersNote: EOS means “End of String”. EO

Seite 62

Controlling Your Optical Power Meter Remotely44 PM-1100Standard Status Data StructureStandard Status Data StructureThe figure shown hereafter illustra

Seite 63 - Optical Power Meter 53

Controlling Your Optical Power Meter RemotelyOptical Power Meter 45Standard Status Data Structure&&&&&&&& ORStandard E

Seite 64 - 54 PM-1100

Controlling Your Optical Power Meter Remotely46 PM-1100Command StructureAn SRQ is forced when a bit is set in the STB and at the same time the corresp

Seite 65 - Recycling and Disposal

Controlling Your Optical Power Meter RemotelyOptical Power Meter 47Error MessagesError MessagesThe Optical Power Meter can manage both system and devi

Seite 67 - 7 Troubleshooting

Optical Power Meter 496 MaintenanceTo help ensure long, trouble-free operation:³ Keep the unit free of dust.³ Store unit at room temperature in a clea

Seite 68 - PM-110X-FOA-XX

ii PM-1100Copyright © 1998–2006 EXFO Electro-Optical Engineering Inc. All rights reserved. No part of this publication may be reproduced, stored in a

Seite 69 - Transportation

Maintenance50 PM-1100Cleaning Detector PortsCleaning Detector PortsRegular cleaning of detectors will help maintain measurement accuracy.To clean dete

Seite 70

MaintenanceOptical Power Meter 51Replacing FusesReplacing FusesThe PM-1100 Optical Power Meter contains two F2.0L250V-type fuses (IEC, 5 mm x 20 mm (0

Seite 71 - 8 Warranty

Maintenance52 PM-1100Recalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025 Standard

Seite 72

MaintenanceOptical Power Meter 53Upgrading the Embedded Software5. If the software upgrade is performed in Windows 98, you must restart your computer

Seite 73 - Service and Repairs

Maintenance54 PM-1100Upgrading the Embedded Software8. If the software upgrade was performed in Windows 2000, an error message is displayed: “LO0006 N

Seite 74 - 64 PM-1100

MaintenanceOptical Power Meter 55Recycling and Disposal (Applies to European Union Only)Recycling and Disposal (Applies to European Union Only)³ Unles

Seite 76

Optical Power Meter 577 TroubleshootingFinding Information on the EXFO Web SiteThe EXFO Web site provides answers to frequently asked questions (FAQs)

Seite 77 - B Remote Control Commands

Troubleshooting58 PM-1100Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical suppor

Seite 78 - 68 PM-1100

TroubleshootingOptical Power Meter 59TransportationTransportationMaintain a temperature range within specifications when transporting the unit. Transp

Seite 79 - Optical Power Meter 69

ContentsOptical Power Meter iiiContentsCertification Information ...

Seite 81 - Optical Power Meter 71

Optical Power Meter 618 WarrantyGeneral InformationEXFO Electro-Optical Engineering Inc. (EXFO) warrants this equipment against defects in material an

Seite 82 - 72 PM-1100

Warranty62 PM-1100LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failu

Seite 83 - Optical Power Meter 73

WarrantyOptical Power Meter 63Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the

Seite 84

Warranty64 PM-1100EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized serv

Seite 85 - Optical Power Meter 75

Optical Power Meter 65A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information presented i

Seite 87 - DISPlay:DIMMer

Optical Power Meter 67B Remote Control CommandsThis section presents detailed information about the commands and queries supplied with your PM-1100 Op

Seite 88 - FETCh[:SCALar]:POWer:DC?

Remote Control Commands68 PM-1100IEEE 488.2 Commands—Quick Reference*CLSDescription This command sets the contents of the Standard Event Register (ESR

Seite 89 - FORMat:READings[:DATA]?

Remote Control CommandsOptical Power Meter 69IEEE 488.2 Commands—Quick Reference*ESR?Description This query reads the contents of the Standard Event S

Seite 90 - INITiate:CONTinuous?

Contentsiv PM-11006 Maintenance ...49Cleaning Detector Po

Seite 91 - INITiate:STORage

Remote Control Commands70 PM-1100IEEE 488.2 Commands—Quick Reference*OPCDescription This command will cause the PM-1100 to generate the “Operation com

Seite 92 - MMEMory:ACQuisition?

Remote Control CommandsOptical Power Meter 71IEEE 488.2 Commands—Quick Reference*RSTDescription This command empties the step response list. It is onl

Seite 93 - MMEMory:ACQuisition:DATA?

Remote Control Commands72 PM-1100IEEE 488.2 Commands—Quick Reference*SREDescription This command sets bits in the Service Request Enable Register (SRE

Seite 94 - 84 PM-1100

Remote Control CommandsOptical Power Meter 73IEEE 488.2 Commands—Quick Reference*TST?Description This query initiates an internal self-test and return

Seite 95 - MMEMory:ACQuisition:DURAtion

Remote Control Commands74 PM-1100Product-Specific Commands—Quick ReferenceProduct-Specific Commands—Quick ReferenceThe table below contains a summary

Seite 96 - MMEMory:ACQuisition:SAMPles?

Remote Control CommandsOptical Power Meter 75Product-Specific Commands—Quick ReferenceMMEM ACQ? (0|1) Acquisition in progress?ACQ DATA? (0 to 1025) Ge

Seite 97 - READ[:SCALar]:POWer:DC?

Remote Control Commands76 PM-1100Product-Specific Commands—Quick Reference* These commands are not executed if a data acquisition is in progress. The

Seite 98 - SENSitivity:AVERage:STATe?

Remote Control CommandsOptical Power Meter 77Product-Specific Commands—DescriptionProduct-Specific Commands—DescriptionABORtDescription This command s

Seite 99 - SENSitivity:FREQuency?

Remote Control Commands78 PM-1100Product-Specific Commands—DescriptionDISPlay:DIMMer?Description This query returns the intensity of the PM-1100 displ

Seite 100 - SENSitivity:POWer:REFerence?

Remote Control CommandsOptical Power Meter 79Product-Specific Commands—DescriptionFORMat:READings[:DATA]Description This command changes the resolutio

Seite 101 - Optical Power Meter 91

Certification InformationOptical Power Meter vCertification InformationF.C.C. InformationElectronic test equipment is exempt from Part 15 compliance (

Seite 102 - SENSitivity:POWer:UNIT?

Remote Control Commands80 PM-1100Product-Specific Commands—DescriptionINITiate:CONTinuousDescription This command starts or stops continuous mode. Whe

Seite 103 - SYSTem:ERRor?

Remote Control CommandsOptical Power Meter 81Product-Specific Commands—DescriptionINITiate[:IMMediate]Description This command stores a value in the i

Seite 104 - UNIT:POWer

Remote Control Commands82 PM-1100Product-Specific Commands—DescriptionMMEMory:ACQuisitionDescription This command initiates a data acquisition with th

Seite 105 - C SCPI-Based Errors

Remote Control CommandsOptical Power Meter 83Product-Specific Commands—DescriptionMMEMory:ACQuisition:DATA?Description This command returns the number

Seite 106 - Description Probable Cause

Remote Control Commands84 PM-1100Product-Specific Commands—DescriptionMMEMory:ACQuisition:DATA:RECAll:VALUE?Description This command returns the measu

Seite 107 - Optical Power Meter 97

Remote Control CommandsOptical Power Meter 85Product-Specific Commands—DescriptionMMEMory:ACQuisition:DELeteDescription This command clears the 1024 m

Seite 108

Remote Control Commands86 PM-1100Product-Specific Commands—DescriptionMMEMory:ACQuisition:SAMPlesDescription This command changes the samples paramete

Seite 109 - Optical Power Meter 99

Remote Control CommandsOptical Power Meter 87Product-Specific Commands—DescriptionREAD[:SCALar]:POWer:DC?Description This query returns the measuremen

Seite 110

Remote Control Commands88 PM-1100Product-Specific Commands—DescriptionSENSitivity:AVERage[:STATe]Description This command activates or deactivates dat

Seite 111

Remote Control CommandsOptical Power Meter 89Product-Specific Commands—DescriptionSENSitivity:CORRection:OFFSet[:MAGNitude]Description This command se

Kommentare zu diesen Handbüchern